INSTALLATION
4
INSTALLATION
PROCEDURES
Unpacking Precautions
The unit is shipped bolted to its mounting pad, ready for
installation.Avoid damage from dropping, bumping, collision,
etc. Store and unpack carton with the proper side up, as
noted on the shipping carton.
Delivery Inspection
After removing the carton, carefully inspect the Home
Generator System for any damage that may have occurred
during shipment.
IMPORTANT: If loss or damage is noted at time of
delivery, have the person(s) making delivery note all damage
on the freight bill and affix his signature under the
consignor's memo of loss or damage. If loss or damage is
noted after delivery, separate the damaged materials and
contact the carrier for claim procedures. Missing or
damaged parts are not warranted.
Shipment Contents
The Home Generator System is supplied with:
Home Generator System
Pre-attached mounting pad
One 24” flexible hook-up hose
Installation and start-up manual
Operator’s manual
Illustrated parts list manual
Installation checklist
Two access door keys
Four lifting hole plugs
Oil fill spout
One spare 15A fuse
2 Pole connector - 240V from house
10 Pole connector - Sensing and control wires
Air intake engine cover
Alternator cover
Diagnostic LED kit (red LED/plate/screws (2))
Required Specialty Tools/Equipment
Two 48” lengths of 1” OD pipe (NOT conduit)
Hole punches for 16ga steel
Torque screwdriver, 5 to 50 inch-pound range
Home Generator System Location
Before installing generator, consult with homeowner and
convey the following guidelines which may affect the
desired location.
Generator Clearances
Place generator in a well ventilated area, which will allow for
removal of deadly exhaust gas. DO NOT install generator
where exhaust gas could accumulate and enter inside or be
drawn into a potentially occupied building. Ensure exhaust gas
is kept away from any windows, doors, ventilation intakes or
other openings that can allow exhaust gas to collect in a
confined area (Figure 1). Prevailing winds and air currents
should be taken into consideration when positioning generator.
Observe that the 15 Amp fuse has been removed from the
control panel for shipping.
DO NOT install this fuse until all plumbing and wiring has
been completed and inspected.
Installing the 15A fuse could cause the engine to start.
CAUTION
Operate generator ONLY outdoors.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes or other openings.
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea,
fainting or death.
WARNING
Keep at least 5 ft. (152 cm) clearance on all sides of generator
including overhead.
Exhaust heat/gases can ignite combustibles or
structures causing a fire.
WARNING
Figure 1 — Home Generator System Clearances
Exhaust port must be
5 ft (152 cm)
minimum distance
from building openings
Exhaust Port